Gas Counters,rement of radiation shortly thereafter, even though scintillants were for a long time in use for the detection of radiation. The original Geiger counter was similar in construction to that of Fig. 3.1. It had an outer cylindrical electrode and an inner wire electrode with a potential difference appl

decipher 发表于 2025-3-23 17:35:48

http://reply.papertrans.cn/48/4740/473973/473973_12.png

Dappled 发表于 2025-3-23 18:27:38

Semiconductor Detectors,uces positive ions and electrons and an electrical signal is obtained by collecting these ions. In a semiconductor counter the incident radiation produces electrons and holes and information about the radiation is obtained by collecting them. One major difference of course is that only 3.5 eV has to

Infant 发表于 2025-3-24 00:24:27

http://reply.papertrans.cn/48/4740/473973/473973_14.png

光亮 发表于 2025-3-24 02:25:10

http://reply.papertrans.cn/48/4740/473973/473973_15.png

NAG 发表于 2025-3-24 09:30:02

Book 1975urpose of this book is to present a survey of the developments in semiconductor detectors along with discus­ sions about gas counters and scintillation counters. These discus­ sions are directed to detector users, usually scientists and technicians in different fields such as chemistry, geology, bio

伴随而来 发表于 2025-3-24 14:19:16

http://reply.papertrans.cn/48/4740/473973/473973_17.png

北极人 发表于 2025-3-24 15:26:26

Semiconductor Detectors, be expended to produce an electron-hole pair in a semiconductor, while the value is ≈30 eV in an ionization chamber. The lower energy increases the number of electron-hole pairs per MeV of radiation and decreases the relative statistical variation in this number. Hence the energy resolution is increased, that is, R is decreased.

olfction 发表于 2025-3-24 21:17:30

Gas Counters,er was similar in construction to that of Fig. 3.1. It had an outer cylindrical electrode and an inner wire electrode with a potential difference applied between them. Geiger found that, when a radiation was stopped in the counter, a current flowed through the electrodes which was detectable with an electrometer of “moderate sensibility.”

固执点好 发表于 2025-3-24 23:57:29

Scintillation Counters,n 1944, Curran and Baker replaced the use of the naked eye by a photomultiplier and later Kallmann replaced the small, thin crystals of ZnS by naphthalene. These two changes revolutionized scintillation detection, making it possible to detect, record, and analyze electronically the pulses produced by individual radiations.
页: 1 [2] 3 4
查看完整版本: Titlebook: Introduction to Nuclear Radiation Detectors; P. J. Ouseph Book 1975 Plenum Press, New York 1975 behavior.chemistry.development.electron.en