Mass Spectrometry in Clinical Laboratory: Applications in Therapeutic Drug Monitoring and Toxicologo present “off-the-shelf” and “ready-to-use” protocols of recent developments in new assays to help the clinical laboratory community adopt the technology and analysis for the betterment of patient care.好色 发表于 2025-3-23 17:50:15
Quantitative LC-MS/MS Analysis of Amphetamines and Cocaine in Human Urine,t response for each analyte at a given concentration is normalized against stable isotope-labeled internal standard. In addition, the assay can be multiplexed across more than one LC channel to obtain high-sample throughput.过于光泽 发表于 2025-3-23 21:04:41
Quantitative LC-MS/MS Method for the Simultaneous Measurement of Six Antiepileptics and Pentobarbittopiramate, zonisamide) and that of pentobarbital by LC-MS/MS. Liquid-liquid sample extraction is followed by reversed-phase chromatography using biphenyl HPLC column and gradient elution. Two MRM transitions are monitored for each drug, and their heavy isotope labeled internal standards. Six-pointOATH 发表于 2025-3-24 00:33:29
Analysis of Barbiturates in Urine by LC-MS/MS, method helps gain efficiency in a high-volume laboratory environment. Additional features of this protocol that help in efficiency gain are automated extraction using Hamilton™ liquid handling system and algorithmic data review using Ascent™ software.边缘带来墨水 发表于 2025-3-24 03:39:02
http://reply.papertrans.cn/23/2278/227757/227757_15.pnginfatuation 发表于 2025-3-24 07:49:41
http://reply.papertrans.cn/23/2278/227757/227757_16.pngResistance 发表于 2025-3-24 13:04:07
Determination of Busulfan and Melphalan in Plasma by Turbulent Flow Chromatography-Tandem Mass Speccted from plasma with methanol containing deuterated internal standards. Turbulent flow chromatography coupled with reversed-phase HPLC was used for separation, while the mass spectrometer was set in the positive ion mode. This method has proven accurate and rapid and allowed for timely dose adjustmWAX 发表于 2025-3-24 15:56:18
http://reply.papertrans.cn/23/2278/227757/227757_18.png经典 发表于 2025-3-24 21:18:11
https://doi.org/10.1007/3-7908-1668-Xwith a bias of −0.2–5%. The intra- and inter-day imprecision were less than 5.0% for all the analytes. The linear assay ranges were 0.3–26 μg/mL for GPN, 0.15–24 μg/mL for LCM, 7.4–1881 ng/mL for PER, 0.03–13 μg/mL for PRG, 0.78–90 μg/mL for RFM, and 0.3–43 μg/mL for VGB.珊瑚 发表于 2025-3-25 00:59:54