书目名称Ultrasound Energy and Data Transfer for Medical Implants影响因子(影响力)<br> http://impactfactor.cn/if/?ISSN=BK0940607<br><br> <br><br>书目名称Ultrasound Energy and Data Transfer for Medical Implants影响因子(影响力)学科排名<br> http://impactfactor.cn/ifr/?ISSN=BK0940607<br><br> <br><br>书目名称Ultrasound Energy and Data Transfer for Medical Implants网络公开度<br> http://impactfactor.cn/at/?ISSN=BK0940607<br><br> <br><br>书目名称Ultrasound Energy and Data Transfer for Medical Implants网络公开度学科排名<br> http://impactfactor.cn/atr/?ISSN=BK0940607<br><br> <br><br>书目名称Ultrasound Energy and Data Transfer for Medical Implants被引频次<br> http://impactfactor.cn/tc/?ISSN=BK0940607<br><br> <br><br>书目名称Ultrasound Energy and Data Transfer for Medical Implants被引频次学科排名<br> http://impactfactor.cn/tcr/?ISSN=BK0940607<br><br> <br><br>书目名称Ultrasound Energy and Data Transfer for Medical Implants年度引用<br> http://impactfactor.cn/ii/?ISSN=BK0940607<br><br> <br><br>书目名称Ultrasound Energy and Data Transfer for Medical Implants年度引用学科排名<br> http://impactfactor.cn/iir/?ISSN=BK0940607<br><br> <br><br>书目名称Ultrasound Energy and Data Transfer for Medical Implants读者反馈<br> http://impactfactor.cn/5y/?ISSN=BK0940607<br><br> <br><br>书目名称Ultrasound Energy and Data Transfer for Medical Implants读者反馈学科排名<br> http://impactfactor.cn/5yr/?ISSN=BK0940607<br><br> <br><br>Preserve 发表于 2025-3-21 23:27:13
Introduction,stic waves to energize and transmit information within the human body. To this end new implanted medical devices (IMDs) are appearing among health monitoring applications which exploit the capability of acoustic waves to penetrate deeper in the body tissue without being significantly attenuated, andAntioxidant 发表于 2025-3-22 02:08:22
Ultrasound in Medicine,ues for deeply implanted devices remain numerous, especially miniaturization and power consumption challenges, which are related. In addition, because of the body’s dielectric nature, communicating with implants that are located deep within the body, using conventional techniques like Radio Frequencexquisite 发表于 2025-3-22 06:27:30
Regulations and System Specifications,e analogies with similar systems in order to define user requirements (e.g. weight and size of the medical device) and test procedures (e.g. in-vitro, in-vivo). In addition, different organizations give directions for ultrasound use to avoid potential injuries due to thermal (e.g. energy is converteidiopathic 发表于 2025-3-22 10:18:00
System Architecture: Control Unit,, and transducer selections were given by conforming FDA regulations in terms of maximum acoustic intensity (.. and ..). Here, the architecture of the control unit is presented. Specifically, the circuit description addresses choices in the wireless energy transmission and half-duplex communication.博爱家 发表于 2025-3-22 16:42:02
System Architecture: Transponder, description addresses choices in the wireless energy transmission and half-duplex communication. Figure 5.1 shows the block diagram of the system architecture, where on the left side there is the control unit (CU) and on the right side the transponder (TR). The CU is made up of the following blocks不整齐 发表于 2025-3-22 20:12:56
Wireless Power Transfer (WPT) and Communication,unication. In Chap. ., the control unit (CU) architecture to drive a spherical array transducer is presented along with details about the front-end and back-end electronics. In Chap. ., the transponder (TR) architecture is shown with important considerations on energy harvesting and speed limits dueBACLE 发表于 2025-3-22 22:17:38
http://reply.papertrans.cn/95/9407/940607/940607_8.pnggraphy 发表于 2025-3-23 05:23:03
http://reply.papertrans.cn/95/9407/940607/940607_9.pngflimsy 发表于 2025-3-23 05:45:21
Regulations and System Specifications,d into heat) and mechanical bioeffects (e.g. cavitation). In this chapter exposure limits to ultrasound for human tissues (e.g. cardiac) are introduced so that system specifications (e.g. operating frequency and transducers selection) can be derived.