Analysis of Microclimate in a Historical Building to Assess the Probability of Recurrence of Filamegi is possible due to exposure of walls with high values of RH (above 70 %) for a prolonged period. The development of this type of analysis intended to indicate strategies to control the filamentous fungi growth from the microclimate control and ongoing maintenance of the historic building materials.

asthma 发表于 2025-3-27 07:56:28

http://reply.papertrans.cn/83/8232/823135/823135_33.png

Spirometry 发表于 2025-3-27 12:39:02

Analysis of Main Parameters that Affect Contact Area Between Mortar Rendering and Substrate: Use ofn on the contact area of rendering mortars. Three different substrates were selected with distinct wetting behaviors: polyethylene, acrylic, and glass. The contact angle of drop water was measured by goniometer. Mortars were prepared with cement:lime:sand ratios of 1:0:3, 1:1:6, and 1:2:9, by conten

反复拉紧 发表于 2025-3-27 16:40:18

http://reply.papertrans.cn/83/8232/823135/823135_35.png

Urgency 发表于 2025-3-27 19:39:17

Criteria for Identification of Ceramic Detachments in Building Facades with Infrared Thermography,raphy to evaluate building facades subjected to sun incidence has allowed interesting advances in the identification of regions with initial detachments that are not visible on the facade surfaces. There are, however, several difficulties in the methodology, especially regarding the best moment to v

违法事实 发表于 2025-3-28 01:48:39

http://reply.papertrans.cn/83/8232/823135/823135_37.png

错误 发表于 2025-3-28 04:52:17

The Wind-Driven Rain and the Buildings: Directional Driving Rain, Experimental Simulation and Quantnteraction with the buildings. In this sense, research discusses some aspects related to driving rain, such as the development and application of a methodology for quantifying wetting areas on models exposed to experimental driving rain, and the determination to the direction of the driving rain, in

custody 发表于 2025-3-28 08:04:04

A Performance Assessment of Prefabricated Bathrooms Installed in the 1990s,with emphasis on wet rooms made as part of a Danish research project—Project Renovation. In this project, 19 different types of bathrooms were made in new untraditional ways. A number of these bathrooms covering 11 different types were surveyed after approximately 20 years of use. The survey aimed a

流浪者 发表于 2025-3-28 13:35:23

http://reply.papertrans.cn/83/8232/823135/823135_40.png
页: 1 2 3 [4] 5
查看完整版本: Titlebook: Recent Developments in Building Diagnosis Techniques; João M.P.Q. Delgado Book 2016 Springer Science+Business Media Singapore 2016 Buildin