入伍仪式 发表于 2025-3-26 22:51:45

Results on R from PEP, PETRA, TRISTAN, and SLCf mass energies between 7 and 93 GeV. At the highest TRISTAN energies, the tail of the .. resonance does increase . by 50%. Such a sizeable increase allows a direct measurement of ... However, this measurement turns out to be somewhat below the direct value measured at SLC at energies around the ..-

咆哮 发表于 2025-3-27 03:22:17

Multiple Soft Photon Bremsstrahlung on the Z Resonanceation near the . resonance. Our results are based on a modified soft photon approximation that respects the resonant character of the matrix element. Also the influence of a cutoff for the total radiated energy is investigated.

有帮助 发表于 2025-3-27 06:52:37

http://reply.papertrans.cn/83/8206/820517/820517_33.png

GULLY 发表于 2025-3-27 13:20:29

Renormalization Scheme Dependence of Electroweak Radiative Correctionsnteractions of gauge fields, Higgs boson and top quark interactions or similar effects from ., expected to be of the order of about 1%. Their detection requires both experimental and theoretical uncertainties to be not more than 0.1%. Typically the expected level of accuracy for various observables

采纳 发表于 2025-3-27 16:23:36

Light Quark Loopshe known fermions is rather large and equivalent to a change of the QED fine structure constant . from its low energy value to the LEP energy scale by about 6%. It can be calculated exactly in the case of leptons.

Cloudburst 发表于 2025-3-27 17:58:43

One-Loop Flavour-Changing Neutral Currents in the Standard Modelooft-Feynman gauge, and the on-shell renormalization scheme is used. The results for on-shell quarks and for the gluon and photon vertices are compared with the ones derived using the usual approximation of neglecting the external quark masses. This approximation is shown to be unreliable.

antedate 发表于 2025-3-27 23:18:32

Generalized Radiative Corrections for Hadronic Targetsctro-magnetic scattering on hadronic targets remains that given in the ’60s by Y. S. Tsai. for structureless spin zero bosons. However, with the enhanced accuracy of new experimental data — the error is currently down to 1–2% on electron scattering cross sections -, and the improvements in theoretic

人造 发表于 2025-3-28 03:53:39

http://reply.papertrans.cn/83/8206/820517/820517_38.png

Lyme-disease 发表于 2025-3-28 09:31:35

http://reply.papertrans.cn/83/8206/820517/820517_39.png

使迷醉 发表于 2025-3-28 10:57:11

0258-1221 989. The Workshop was weIl timed: the day after its concluding session the first beam at LEP was circulated. The Original aims of the Workshop were twofold: first to review the existing theoretical work on electroweak radiative corrections in the light of the initial experiments at SLC and LEP, and
页: 1 2 3 [4] 5 6
查看完整版本: Titlebook: Radiative Corrections; Results and Perspect N. Dombey,F. Boudjema Book 1990 Springer Science+Business Media New York 1990 electron.hadron.q