Oligarchy 发表于 2025-3-27 00:21:55

Can Central-Venous Replace Mixed-Venous Oxygen Saturation Measurements during Anesthesia?s the metabolic demands of the various tissues. Measurements of mixed venous oxygen saturation (SmvO.) have been used to assess the adequacy of tissue oxygenation under various clinical conditions (Valentine et al. 1966, Lee et al. 1972, Divertie et al. 1984). Although SmvO. depends on a large numbe

纵欲 发表于 2025-3-27 04:09:50

In Line Monitoring of Carbon Dioxide Via a Gas Permeable Windowp, has been previously reported by the authors.. This system is now in routine clinical use (Cardiomet 1000, Orange Medical Instruments, High Wycombe, England). This technique has several clinical advantages. Firstly, the sensor is separated from the circulating fluid by a sterile barrier and need n

Delude 发表于 2025-3-27 06:59:58

http://reply.papertrans.cn/71/7054/705368/705368_33.png

小歌剧 发表于 2025-3-27 10:26:09

http://reply.papertrans.cn/71/7054/705368/705368_34.png

急性 发表于 2025-3-27 17:15:42

P NMR Evaluation of Hypoxic Stress in Brain of Animal Modelsternum of neonates affords ideal conditions for NMR evaluation of impaired oxidative metabolism (2,3). Brains of animal models (dog and cat) are best studied with muscles retracted with the rf coil placed on the bare skull.. P and .H (lactate) signals are time shared with a doubly tuned coil (4). Se

凹处 发表于 2025-3-27 18:46:28

http://reply.papertrans.cn/71/7054/705368/705368_36.png

anthropologist 发表于 2025-3-27 23:11:05

Estimation of Concentration Ratios and the Redox States of the Cytochromes from Noisy Reflection Spespectra using a set of basic absorption spectra, which describe the single chromophoric substances of the multicomponent system, and applying the Kubelka-Munk algorithm (Kubelka and Munk, 1931; Hoffmann et al., 1984). Since basic absorption spectra differ in distinctness and sharpness of absorption

dendrites 发表于 2025-3-28 05:38:15

http://reply.papertrans.cn/71/7054/705368/705368_38.png

无瑕疵 发表于 2025-3-28 10:07:35

http://reply.papertrans.cn/71/7054/705368/705368_39.png

无所不知 发表于 2025-3-28 13:20:36

O2 Optodes for Analyzing Micro Blood Samples Using Thin Sensor Layers with Small O2 Capacities and Sd Opitz, 1983) or on organ surfaces (Opitz and Lübbers, this volume). However, with measurements in different samples, e.g. blood and gas, reflection changes occur at the optical phase transition sensor/ medium due to different optical densities of the various media to be measured. These reflection
页: 1 2 3 [4] 5 6 7
查看完整版本: Titlebook: Oxygen Transport to Tissue VIII; Ian S. Longmuir Book 1986 The Editor(s) (if applicable) and The Author(s), under exclusive license to Spr