Truculent 发表于 2025-3-26 22:40:27
http://reply.papertrans.cn/71/7026/702529/702529_31.pngmenopause 发表于 2025-3-27 02:30:55
Utility of OCT for Detection or Monitoring of Glaucoma in Myopic Eyestection of glaucoma as well as for progression analysis. Clinicians should be familiar with the practical aspects and cognizant of the pitfalls of OCT imaging in patients with myopia with or without glaucoma.发誓放弃 发表于 2025-3-27 08:28:05
Optical Coherence Tomography and Progressionthe approaches used by the software and need to understand the limitations of the current OCT systems. This chapter summarizes the basic methods used by progression detection software and the latter’s role in clinical practice. If used correctly, OCT progression analysis is a solid tool for monitoring early glaucoma.不爱防注射 发表于 2025-3-27 12:20:12
Optical Coherence Tomography: Introduction, History and Current Statusar structures. During the last decade, this technique has been rapidly adopted into clinical practice and has become an essential tool for both diagnosis and monitoring of glaucoma. OCT is able to acquire concurrent images of the optic nerve head, retinal nerve fiber layer and macular inner layers a生气的边缘 发表于 2025-3-27 15:04:01
Optical Coherence Tomography: Basics and Technical Aspectsimages from transparent or semi-transparent tissues with a penetration depth of 2–4 mm and a resolution similar to a low power microscope. It is a non-contact, non-invasive imaging technique used to obtain high-resolution cross-sectional images of the ocular structures. OCT imaging of the retina or杂色 发表于 2025-3-27 20:02:53
Role of Optical Coherence Tomography in Glaucomatoring of glaucoma as it can detect RGC damage objectively and quantitatively. OCT can demonstrate changes related to RGC damage in three anatomical domains. Retinal nerve fiber layer (RNFL) analysis has been a primary outcome of interest and can establish loss of RGC axons. Macular ganglion cell anNATAL 发表于 2025-3-27 23:32:27
Optical Coherence Tomography: Manufacturers and Current Systemsanufacture OCT systems. Some of these systems are incorporated in various ophthalmic devices like femtosecond lasers, biometry devices, and surgical microscopes. However, most of the current OCT devices consist of diagnostic OCT systems that are used clinically for detection and monitoring of glaucoHarass 发表于 2025-3-28 05:36:47
http://reply.papertrans.cn/71/7026/702529/702529_38.png粗糙滥制 发表于 2025-3-28 07:51:44
Interpretation of Imaging Data from Spectralis OCTistration, and advanced segmentation algorithms of the optic nerve head, retinal nerve fiber layer and macular region. These systems have established themselves as the predominant imaging modality for management of glaucoma, providing high-resolution visualization of ocular microstructures and objec串通 发表于 2025-3-28 13:27:56
Examples of Optical Coherence Tomography Findings in Glaucoma Eyes with Varying Stages of Severityical Coherence Tomography (OCT) is the current gold standard for structural testing in glaucoma. We present cases with varying severity of glaucomatous damage in this chapter. The aim is to familiarize the reader with a step-by-step approach for diagnosing and staging glaucoma by evaluating the OCT