两种语言 发表于 2025-3-23 13:04:51
Environmental Analysis with the FT-IR System K300: Examples and Resultsd tests in Berlin. These investigations have been conducted in the frame of a research project, funded by the German Ministry of Research and Technology in cooperation with the Fraunhofer-Institute of Atmospheric Environmental Research in Garmisch-Partenkirchen/Germany. Special emphasis has been put步履蹒跚 发表于 2025-3-23 15:45:04
Verfahren zur passiven und aktiven Fernsondierung von Spurengasen auf der Basis der Fourier-Transforungsluft operationell eingesetzt. Die gemessenen Infrarot-Spektren von natürlichen oder künstlichen Strahlungsquellen werden mit PC-Programmen auf der Basis der Strahlungstransporttheorie ausgewertet. Damit können aus der Emission oder Absorption der Strahlung die Konzentrationen von CO, N.O, CH., C协定 发表于 2025-3-23 21:36:03
Single-Longitudinal-Mode (SLM) Generation at Power Diode Lasers by Using a Diffracto-Optical Externair. Laser spectroscopic methods and Lidar among these are able to solve some of that tasks. Laser analytical investigations make necessary tunable laser sources. For mobile operations at satellites or aeroplanes a lidarsystem has to be small, light, compact, robust and reliable. The improvement of sbadinage 发表于 2025-3-24 01:41:48
http://reply.papertrans.cn/59/5817/581627/581627_14.png肌肉 发表于 2025-3-24 04:21:45
Aerosol Backscatter Measurements Using a Compact CO2 Lidar Sensorent, on human health or might cause hazardous industrial accidents. Conventional air monitoring techniques detect only nearby pollutants and thus yield limited information on the pollutants’ local distribution. As a consequence concentrations with strong spatial variations may not be detected at all征税 发表于 2025-3-24 10:28:52
http://reply.papertrans.cn/59/5817/581627/581627_16.pngconifer 发表于 2025-3-24 11:21:55
http://reply.papertrans.cn/59/5817/581627/581627_17.pngPalliation 发表于 2025-3-24 14:56:22
Line-Tunable Electronic-to-Vibrational Energy Transfer Lasers in the Mid-Infrared most molecules show characteristic absorption spectra. Laser based chemical analysis in the wavelength region 2.8.m ≤ λ ≤8.5.m usually employs lead sulfide diode lasers, which are tuned by varying the diode current and diode temperature in the temperature range below 100K. However, these lasers do粗语 发表于 2025-3-24 22:50:28
Time-Resolved Chlorophyll Fluorescence for Monitoring of Forest Declineous custom made kinetic equipments. Both kinetics in the picosecond and in the seconds time range could be fitted by three exponentially decaying components yielding three amplitudes and three reaction constants each. Basically, all components showed a typical annual time course, independent of the暗指 发表于 2025-3-25 02:05:40
Picosecond Fluorescence Decay and Backscattering Measurements of Vegetation over Distancesmperature, CO. or the presence of some kinds of pollutants. An understanding of these interactions at a large scale (field, land or global scale) can only be made if remote sensing techniques are used. In the last decades, several spectroscopic methods have been considered for characterizing plant s