钢笔尖 发表于 2025-3-23 10:20:31
Clinical Implications of Component Modularity in Total Hip Replacementided the surgeon with the intraoperative flexibility to fine tune adjustments of limb length, offset, anteversion, head size, the requirement for and position of extended lip liners, etc. However, the levy for these benefits is the associated risk of fretting, corrosion, accelerated polyethylene wear, dissociation, etc.Pericarditis 发表于 2025-3-23 17:40:41
Importance of Prosthesis Design and Surface Structure for the Primary and Secondary Stability of Unce implant bed, and the interaction between the implant material and the bone stock. The fate of a cementless artificial joint is decided at the interface or boundary between the bone and the implant, where living tissue meets bioinert (i.e. non-living) material. Numerous causes of loosening of aseptic implants have been identified.营养 发表于 2025-3-23 21:42:25
Polyethylene as a Bearing Surfaceclinical problem that limits the longevity of orthopaedic implants. Excessive wear may lead to gross mechanical failure such as fracture and disas-sociation and the release of particulate wear debris may induce biological responses that cause implant loosening .评论者 发表于 2025-3-24 01:02:38
http://reply.papertrans.cn/48/4710/470937/470937_14.pngjudiciousness 发表于 2025-3-24 02:25:40
https://doi.org/10.1007/978-1-4471-0477-3Interface; Mechanics; arthroplasty; bone; fixation; hip; hip arthroplasty; implant; orthopaedic surgery; pain亲密 发表于 2025-3-24 09:52:03
Ian D. Learmonth (Professor and Head, Honorary ConAddresses the important issues and factors influencing the component cement and bone cement interface that contribute to durability of fixation.Examines and evaluates combinations of materials to deteDefense 发表于 2025-3-24 12:31:01
http://reply.papertrans.cn/48/4710/470937/470937_17.pngAbduct 发表于 2025-3-24 16:39:17
Titanium Femoral Component Fixation and Experience with a Cemented Titanium Prosthesisthat this dement should be called “Menaccanite” as it had been found near the village of Menaccan. At the same time in Germany the chemist, Klaproth found a similar mineral and referring to the mythological children of Mother Earth named it “Titanium” after the “Titans” .仇恨 发表于 2025-3-24 20:25:55
The Time-dependent Properties of Polymethylmethacrylate Bone Cement: the Interaction of Shape of Femderstood of the implant components — it has been blamed for early failure, it has been called the “weak link” in the replacement joint system, etc. In order for bone cement to be used successfully in long-term fixation of a total replacement hip joint, the femoral and acetabular components must be dclarify 发表于 2025-3-25 01:51:03
http://reply.papertrans.cn/48/4710/470937/470937_20.png