壮丽的去 发表于 2025-3-23 10:28:30

IRT Versus Drying: In Situ Tests in Outdoor Environment,e detector was also used to qualitatively assess the evolution of the moisture content of the walls. The walls under study were coated with similar rendering and painting, but they presented different exposure to solar and thermal radiation.

Mri485 发表于 2025-3-23 15:37:48

http://reply.papertrans.cn/47/4663/466287/466287_12.png

CRANK 发表于 2025-3-23 19:05:13

2191-530X ls due to wind-driven rain infiltrations, and the drying process. ..The book equips readers with a deeper understanding of the ideal conditions for accurate IRT assessment and offers practical recommendations. .978-3-319-75385-0978-3-319-75386-7Series ISSN 2191-530X Series E-ISSN 2191-5318

Mnemonics 发表于 2025-3-24 00:48:32

IRT Versus Moisture: Laboratory Tests,rmal images were taken during the drying period, which lasted about 10 days. For the two phenomena, besides thermal images, a moisture detector was also used to qualitatively evaluate the moisture content of the walls.

institute 发表于 2025-3-24 02:37:42

Measurement of Surface Temperature Using Different Devices,y discussed in this chapter, including a comparison between the values obtained using three different devices (infrared camera, infrared thermometer and type T thermocouples). The chapter describes the methodology and the results attained in two experimental campaigns, one in situ and the other one

Comedienne 发表于 2025-3-24 08:51:08

http://reply.papertrans.cn/47/4663/466287/466287_16.png

COM 发表于 2025-3-24 11:54:46

IRT Versus Moisture: In Situ Tests in Indoor Environment,implemented and moisture was detected due to the effect of evaporative cooling. Moisture in the walls under study had two different sources: rising damp and infiltration of rainwater. Rising damp was assessed in an exterior wall of a basement in a residential building, and infiltration of rainwater

中古 发表于 2025-3-24 18:52:48

IRT Versus Drying: In Situ Tests in Outdoor Environment,al phenomenon underlying these measurements was the effect of evaporative cooling, and the passive approach was implemented. Simultaneously, a moisture detector was also used to qualitatively assess the evolution of the moisture content of the walls. The walls under study were coated with similar re

缓和 发表于 2025-3-24 22:04:00

Eva Barreira,Ricardo M. S. F. Almeidaezifische Konstruktion des »homme naturel« zu differenzieren in ihren männlichen und weiblichen Teil. Choderlos de Laclos hat in den achtziger Jahren drei Essays geschrieben, die unter dem Titel des zweiten . (Von den Frauen und ihrer Erziehung) zusammengefaßt sind.. Dieser zweite Essay ist die frag

clarify 发表于 2025-3-25 02:09:00

Eva Barreira,Ricardo M. S. F. Almeidale in der Nachfolge Rousseaus geschriebenen Texte zur . zeugen von der weiten Verbreitung des . und der . in der zweiten Hälfte des 18. Jahrhunderts. Die durchschlagende Wirkung dieses Frauenbildes ist nicht nur mit sozialgeschichtlichen Gründen zu erklären und schon gar nicht auf ein patriarchalisc
页: 1 [2] 3 4
查看完整版本: Titlebook: Infrared Thermography for Building Moisture Inspection; Eva Barreira,Ricardo M.S.F. Almeida Book 2019 The Author(s), under exclusive licen