未成熟 发表于 2025-3-25 06:40:06

http://reply.papertrans.cn/47/4639/463837/463837_21.png

Countermand 发表于 2025-3-25 08:30:05

Indoor Environmental Quality Assessment in a Newly Renovated Office Building in Delhi City,io of pollutants, indoor air quality during working and non-working hours etc. The study also emphasized on the emission of pollutants due to cooking practices in the canteen area. The findings of the study highlight the effect of ventilation rate in the office building, office and canteen activitie

ANTI 发表于 2025-3-25 12:18:22

Indoor Particulate Matter Pollution on Oxidative Stress Pathways: Role of Chemical and Biological Cth sized PM revealing a significant health risk due to their association with various respiratory tract infections. The cytotoxic profile of indoor PM and their constituents determined by MTT assay on A549 cells exhibited a significant decrease in cell viability indicating the cytotoxic behavior of

judiciousness 发表于 2025-3-25 16:52:07

http://reply.papertrans.cn/47/4639/463837/463837_24.png

lethargy 发表于 2025-3-25 21:58:10

http://reply.papertrans.cn/47/4639/463837/463837_25.png

bronchodilator 发表于 2025-3-26 04:00:13

Quantification of Dynamic Ventilation Rates and Assessment of Occupant Thermal Comfort Inside a Natrtable for approximately 22% of the total time, mainly during the night and early morning hours. A neutral temperature of 22.7 °C and a comfortable temperature range of 20.6–24.6 °C were determined (. = 18.6–24.8 °C). The difference between AER. (0.14–2.67 h.) and AER. (0.31–2.66 h.) was not statist

Bother 发表于 2025-3-26 04:36:39

http://reply.papertrans.cn/47/4639/463837/463837_27.png

代理人 发表于 2025-3-26 11:15:32

A Review of Antimicrobial Air Filters over Normal Air Filters: Unique Insights on SARS-CoV-2 Virus rmal filters have a negative reduction which implies the growth of microorganisms. Structural and filtration integrity of anti-microbial air filters were upheld without affecting the filter‘s porosity and initial pressure drop. There was no statistically significant difference in pressure drop and f

生意行为 发表于 2025-3-26 15:47:12

Advanced Ventilation for Better Health,h of building occupants are presented to justify the need for change of the focus from room ventilation to ventilation for occupants. The present ventilation design based on ventilation rate has to be complimented with ventilation design based on ventilation air distribution. The performance of adva

载货清单 发表于 2025-3-26 20:16:42

Evaluation of Health Risks Associated with Household Air Pollution in Rural Areas of Telangana State across the world that has resulted in 3.2 million deaths per year. In the present study, Particulate Matter (PM. and PM.) were investigated in biomass and LPG based households during summer and monsoon seasons, followed by evaluation of health risks for women in rural areas of Telangana state in I
页: 1 2 [3] 4 5 6
查看完整版本: Titlebook: Indoor Environmental Quality; Select Proceedings o Priyanka Kulshreshtha,Sumanth Chinthala,Barun Agga Conference proceedings 2024 The Edito