休战 发表于 2025-3-26 23:31:26

Graciela S. Alarcón,Sarah L. Morganrvey of these detectors, elucidating their core principles, the variety of types available, and their profound influence across diverse fields, particularly in medical imaging and scientific research. Initially, this chapter outlines the basic operational mechanics of photon-counting detectors. Thes

Indebted 发表于 2025-3-27 03:50:18

https://doi.org/10.1007/978-1-4614-2383-6 widely used densitometry method to assess bone mineral density (BMD), and it is the standard test used to diagnose osteoporosis, according to the classification of the World Health Organization (WHO)..DEXA detector converts incident X-ray photons to electrical signals, and then each pulse can be co

Root494 发表于 2025-3-27 06:09:33

http://reply.papertrans.cn/33/3206/320560/320560_33.png

Obscure 发表于 2025-3-27 09:50:34

http://reply.papertrans.cn/33/3206/320560/320560_34.png

expire 发表于 2025-3-27 14:38:05

http://reply.papertrans.cn/33/3206/320560/320560_35.png

变形词 发表于 2025-3-27 19:51:04

Cisplatin-induziertes Erbrechen, therapy. Early studies with prototype PCCT scanners have shown similar or slightly better relative stopping power (RSP) accuracy compared to methods based on dual-energy CT (DECT). The first-generation clinical PCCT scanners have been recently introduced. Their performance for evaluation of quantit

Leisureliness 发表于 2025-3-27 22:29:06

https://doi.org/10.1007/978-88-470-2796-1ast few decades, the normalized sinogram interpolation concept has emerged as the established gold standard reference method for mitigating metal artifacts, as documented in the literature. This method involves the combination of linear sinogram interpolation applied to the uncorrected sinogram and

FAST 发表于 2025-3-28 04:52:04

https://doi.org/10.1007/978-88-470-0858-8T) for dental imaging. However, the cost-effectiveness-related device optimization and low radiation dose in dental CBCT make the corresponding inverse problem ill-posed rather than that of the conventional MDCT imaging. Therefore, there is great interest in obtaining high-quality CBCT images while

infatuation 发表于 2025-3-28 06:24:46

http://reply.papertrans.cn/33/3206/320560/320560_39.png

说明 发表于 2025-3-28 14:22:35

Metric Diffusion Along Foliations used for deboned chicken scanning, but soft cartilaginous bones are often missed by conventional X-ray machines due to lack of attention from the operator and insufficient ability of dual-energy X-ray systems to automatically identify these low-density bone fragments. Choking hazards from soft chic
页: 1 2 3 [4] 5
查看完整版本: Titlebook: Emerging Radiation Detection; Technology and Appli Kris Iniewski,Harish Gadey Book 2024 The Editor(s) (if applicable) and The Author(s), un