安抚
发表于 2025-3-23 10:47:35
http://reply.papertrans.cn/32/3131/313093/313093_11.png
溺爱
发表于 2025-3-23 16:29:56
Introduction: Overview of the Book,of Subtilisin Carlsberg and . lipase B (CAL B) are described. The combi-PCMC concept is useful both for cascade and non-cascade reactions. It can also be beneficial to combine two different specificities of a lipase when the substrate requires it. Combi-PCMC of CALB and Palatase used for the convers
adequate-intake
发表于 2025-3-23 18:34:56
Africa Background to Exuberance,, there are no general rules for selecting the best support for a giving application. A macroporous copolymer of ethylene glycol dimethacrylate and glycidyl methacrylate (poly (GMA-co-EGDMA)) is a carrier consisting of macroporous beads for immobilizing enzymes of industrial potential for the produc
起波澜
发表于 2025-3-24 01:35:15
Paul Collier,Jan Willem Gunningfor any rate-critical chemical process, particularly sensing or electrochemical applications, once physical or chemical moieties are incorporated into the gels to add their functionality to the ultraporous scaffold. Incorporating biomolecules into aerogels, other than such rugged species as lipases
Eviction
发表于 2025-3-24 02:53:12
African Economies in Transitionssed a major issue that can occur when using these biocatalysts, i.e., slow heterogeneous electron transfer, by incorporation of a redox active species to act as an electron shuttle. There are several advantages to immobilizing both the enzyme and mediator at the enzyme surface, including increased
absolve
发表于 2025-3-24 07:32:43
http://reply.papertrans.cn/32/3131/313093/313093_16.png
增减字母法
发表于 2025-3-24 13:16:50
Alfred Mbeteh,Massimiliano M. Pellegriniaces, which also serve to increase the localized concentration of the biocatalyst. The properties of the employed redox couple must be compatible with the target biocatalyst from both an electrochemical (potential) and biochemical standpoint. This chapter details the synthesis of a naphthoquinone-fu
inhumane
发表于 2025-3-24 16:23:55
https://doi.org/10.1007/978-3-030-18807-8on. Direct heterogeneous electron transfer to glucose oxidase has been shown to be kinetically difficult, which is why electron transfer mediators or indirect detection is usually used for monitoring glucose with electrochemical sensors. It has been found, however, that electrodes modified with sing
不怕任性
发表于 2025-3-24 20:33:07
http://reply.papertrans.cn/32/3131/313093/313093_19.png
Left-Atrium
发表于 2025-3-24 23:21:22
http://reply.papertrans.cn/32/3131/313093/313093_20.png