absolve 发表于 2025-3-25 06:33:31
Fast and Accurate Methods of Plasma Boundary Determination in ITER from External Magnetic MeasuremenThree methods have been developed and examined in numerical experiments: the variable current filament (VCF) method, the fixed current filament (FCF) method and local field expansion (LFE) method for plasma boundary determination in a tokamak from external magnetic measurements.基因组 发表于 2025-3-25 10:26:33
Jiming Peng,Cornelis Roos,Tamás Terlaky of the tokamak. The proposed list of measurements and the detailed measurement specifications - parameter ranges, target measurement resolutions and accuracies - are presented. The principal practical problems that will have to be overcome in implementing the diagnostics are outlined and areas where particular difficulties arise are identified.Anthology 发表于 2025-3-25 14:55:05
M. Altieri,Chr. Becker,S. Turek electron density profiles.. In Amplitude Modulation (AM) reflectometry. the group delay is obtained from the phase delay φ of the modulating envelope as τ.=φ/Ω, where Ω/2π is the modulating frequency; phase measurement is unambiguous provided that Ωτ.<2πBaffle 发表于 2025-3-25 16:19:58
http://reply.papertrans.cn/28/2708/270748/270748_24.png百灵鸟 发表于 2025-3-25 21:47:37
Requirements for ITER Diagnostics of the tokamak. The proposed list of measurements and the detailed measurement specifications - parameter ranges, target measurement resolutions and accuracies - are presented. The principal practical problems that will have to be overcome in implementing the diagnostics are outlined and areas where particular difficulties arise are identified.公社 发表于 2025-3-26 00:25:58
Experimental Results of Amplitude Modulation Reflectometry on High Density Tokamak Plasmas electron density profiles.. In Amplitude Modulation (AM) reflectometry. the group delay is obtained from the phase delay φ of the modulating envelope as τ.=φ/Ω, where Ω/2π is the modulating frequency; phase measurement is unambiguous provided that Ωτ.<2πInfect 发表于 2025-3-26 04:19:47
http://reply.papertrans.cn/28/2708/270748/270748_27.pngATRIA 发表于 2025-3-26 12:10:26
http://reply.papertrans.cn/28/2708/270748/270748_28.pngRODE 发表于 2025-3-26 13:11:50
https://doi.org/10.1007/978-3-031-01730-8orporated in the modifications have simplified the design and facilitated fabrication, assemble and maintenance. The divertor concept remains similar to that of the OD, except a vertical target has been adopted as the first option. The cassette approach retains flexibility and permits rapid changeou厌倦吗你 发表于 2025-3-26 18:00:14
Error Bounds for Quadratic Systems to enable diagnostic design to be done effectively and efficiently with the worldwide distribution of resources. The Joint Central Team has clear responsibility for assuring that the diagnostics being designed give the full capability for machine protection and control of the plasmas and for evalua