Jargon 发表于 2025-3-28 15:50:16

High-Energy Electron-Diffraction and X-Ray Emission Analysis of Surfaces and Their Reaction Products x-ray information may be obtained from such structures simultaneously. Attempts to calibrate the apparatus for carbon and oxygen layers on iron are discussed in some detail. The method appears well suited to the study of kinetic phenomena in surface films of mean thickness less than 100 Å.

冷漠 发表于 2025-3-28 21:40:54

Some Experimental Considerations in Atomic Absorptionsorbance units was obtained for a 10 ppmaqueous standard, depending on the choice of lamp and whether it was used with ac or dc. Advantages and disadvantages of the various possibilities are discussed.

incarcerate 发表于 2025-3-29 02:29:34

Book 1969ng of the Society of Applied Spectroscopy, held (in place of the 19th Mid-America Symposium on Spectroscopy) in Chicago, May 13-17, 1968. These papers, selected by the editors and reviewed by persons knowledgeable in the field, are those of the symposium type and not those pertaining to specific res

vasculitis 发表于 2025-3-29 04:27:30

http://reply.papertrans.cn/28/2702/270153/270153_44.png

大喘气 发表于 2025-3-29 07:49:00

Natalia A. Baires,Mitch Frylingd earlier has been modified to improve the intensity of the secondary x-ray. The modified setup with low-Z kit has been changed to accommodate four analyzing crystals in the vacuum chamber. The radioisotopes dysprosium-159, iodine-125, and others were used with the nondispersive x-ray fluorescence m

chronology 发表于 2025-3-29 12:19:53

http://reply.papertrans.cn/28/2702/270153/270153_46.png

Flustered 发表于 2025-3-29 16:58:57

Luc Anselin,Ibnu Syabri,Youngihn Kho to Al(NO.). was not. Therefore in the nitrous oxide flame it was possible to determine effects of Ca and Al excitation as well as the effects of Al on Ca excitation. The association of Ca ions with PO.. and SO.. in solutions to form probably CaSO. and Ca.(PO.). would be consistent with our results.

NUDGE 发表于 2025-3-29 23:04:18

http://reply.papertrans.cn/28/2702/270153/270153_48.png

影响带来 发表于 2025-3-30 02:30:18

http://reply.papertrans.cn/28/2702/270153/270153_49.png

Mirage 发表于 2025-3-30 06:29:42

Dispersive and Nondispersive X-Ray Fluorescence Methods for the Measurement of the Thicknesses of Fid earlier has been modified to improve the intensity of the secondary x-ray. The modified setup with low-Z kit has been changed to accommodate four analyzing crystals in the vacuum chamber. The radioisotopes dysprosium-159, iodine-125, and others were used with the nondispersive x-ray fluorescence m