Respond 发表于 2025-3-30 11:31:43

Andreas Schnirch,Manuela Welzelrical streaming potentials measured..During the experiments carried out on the model, the actual water flow quantities were consistent with the water flow quantities calculated from the electric field..The empirically determined correlations between the electrical streaming potentials and the quanti

textile 发表于 2025-3-30 12:42:01

http://reply.papertrans.cn/27/2693/269242/269242_52.png

欢乐中国 发表于 2025-3-30 17:27:55

Effect of leaks in dams and trials to detect leakages by geophysikal means,mera was also installed and was used to observe the infrared thermo-reflection of the downstream face of the dam during the leakage tests..The tests showed that even small leaks in sealing faces can lead to considerable water losses and extensive percolations of embankment dams. Local infiltrations

Genistein 发表于 2025-3-30 23:42:30

Numerical modeling of self-potential anomalies due to leaky dams: Model and field examples,features a leakage zone, a seepage area and an earthen dam structure with physical properties similar to the field case considered below. We consider examples where the depth of the leak, the variation of anomalies with flow path, and the effect of a change in rock type within the dam are examined.

AIL 发表于 2025-3-31 03:53:18

http://reply.papertrans.cn/27/2693/269242/269242_55.png

洁净 发表于 2025-3-31 05:07:38

http://reply.papertrans.cn/27/2693/269242/269242_56.png

北京人起源 发表于 2025-3-31 13:04:15

Model experiments on a small test channel. Empirical correlations between flow potentials and the hrical streaming potentials measured..During the experiments carried out on the model, the actual water flow quantities were consistent with the water flow quantities calculated from the electric field..The empirically determined correlations between the electrical streaming potentials and the quanti

Tinea-Capitis 发表于 2025-3-31 15:23:19

Modelling of streaming potentials and thermometrical measurements at a big laboratory channel,water discharge measuring sensor, 80 pressure transducers (piezometers), 20 electrodes of platinum, 25 electrodes of copper sulfate and five tensiometers were installed. All the sensors and electrodes were connected with an automatic PC-controlled scanner system..Several streaming tests were carried

remission 发表于 2025-3-31 20:22:34

The project of the volkswagen foundation "geoelectrics/thermometry",

压倒 发表于 2025-4-1 00:26:58

http://reply.papertrans.cn/27/2693/269242/269242_60.png
页: 1 2 3 4 5 [6] 7
查看完整版本: Titlebook: Detection of Subsurface Flow Phenomena; Georg-Paul Merkler,Heinz Militzer,Josef Brauns Conference proceedings 1989 Springer-Verlag Berlin