Software for Economic Optimal Control Modelsn a pulse travels in a test specimen with sound attenuation the spectrum and the center frequency of the pulse is changed with the traveled sound path. But even the bandwidth-dependent DGS diagram is calculated for a fixed center frequency. A method to derive and to consider the frequency-dependentMetamorphosis 发表于 2025-3-27 03:47:27
Wolf KleinertPresents an approach to bring both sizing methods DGS and DAC close together.Proposes an idea to increase sizing methods productivity significantly.Author with 30+ years experience working in industryannexation 发表于 2025-3-27 07:53:21
http://reply.papertrans.cn/27/2648/264716/264716_33.pngTonometry 发表于 2025-3-27 13:25:22
State of the Art: DAC and DGS,bed. How to derive a special DGS diagram for a certain probe from the general DGS diagram is explained as well as the necessary adaptations for sound attenuation and other influences. Examples for sizing using the DGS method is given for a straight beam probe and for an angle beam probe.文字 发表于 2025-3-27 15:54:34
The New Probe Technology, Single Element Probes, Necessary adaptations are taken into account. The new angle beam probes generate rotationally symmetric sound fields as expected. The DGS accuracy in the working range defined in the EN ISO 16811:2011 is significantly better than the accuracy achieved with traditional angle beam probes.易怒 发表于 2025-3-27 21:27:35
New Probe Technology, Phased Array Probes,ngle of the phased array probe. Not only the delay laws are determined but for each angle all other data needed are determined in this chapter. With this data a special DGS diagram can be derived from the general one for each angle making it easy to use the DGS method for sizing with phased array angle beam probes.单色 发表于 2025-3-27 23:01:00
Convert SDH into FBH and Vice Versa,er. The term equivalent diameters is used when both holes are generating the same amplitude at the given sound path. This method can be applied vice versa calculating a side-drilled hole from a given flat-bottomed hole.妨碍 发表于 2025-3-28 04:46:17
https://doi.org/10.1007/978-3-319-32836-2Distance Amplitude Correction; Distance Gain Size; Non-destructing Testing; Reflector Sizing; Standardizenmesh 发表于 2025-3-28 08:38:32
http://reply.papertrans.cn/27/2648/264716/264716_39.png使厌恶 发表于 2025-3-28 11:38:52
The Court of Justice and the Legal Systembed. How to derive a special DGS diagram for a certain probe from the general DGS diagram is explained as well as the necessary adaptations for sound attenuation and other influences. Examples for sizing using the DGS method is given for a straight beam probe and for an angle beam probe.