https://doi.org/10.1007/978-1-4899-6281-2l question which had to be solved, the solution provided by pressure measurement, and the subsequent treatment. Going through these cases will familiarize the reader with the applications and features of coronary pressure measurement and fractional flow reserve.现代 发表于 2025-3-23 15:23:03
https://doi.org/10.1007/978-1-4899-6281-2lled lumen in the first generation of balloon catheters. Since these early days, the interest in measuring distal coronary pressure has fluctuated between enthusiasm for having a simple index to assess coronary hemodynamics and disillusion due to the inconsistency of the results..ABIDE 发表于 2025-3-23 21:16:58
https://doi.org/10.1007/978-94-015-9564-3arteries; artery; assessment; blood; circulation; evaluation; intervention; outcomeNeutropenia 发表于 2025-3-24 00:38:14
978-90-481-5398-5Springer Science+Business Media Dordrecht 2000护身符 发表于 2025-3-24 02:41:16
s the effect of this stenosis on coronary blood flow and myocardial function?”; as a clinician: “Is this lesion responsible for the patient’s symptoms?”; and finally as an interventionalist: “Will revascularization of this artery improve the patient?”brachial-plexus 发表于 2025-3-24 09:27:04
Is There an Acceptable Level of Use?,ell understood. This chapter does not claim to be an extensive review of the physiology of the coronary circulation but aims at providing the reader with the anatomic and physiologic background required to understand the principles, advantages, and limitations of the concept of pressure-derived frac辞职 发表于 2025-3-24 13:19:31
be improved by the revascularization of that stenosis, are among the most common and important questions in the catheterization laboratory. Traditionally, cardiologists base their clinical decisions about the adequacy or inadequacy of myocardial perfusion in any given patient on inferences or prediarmistice 发表于 2025-3-24 18:54:27
Marie Dayal values, the dependency on hemodynamic loading conditions, and the inability to distinguish the effects of epicardial coronary disease and micro-vascular disease on coronary blood flow.. As a result, there is a wide variation in normal values and a large overlap between normal and pathologic valueConcrete 发表于 2025-3-24 19:34:53
which may lead to erroneous results or misinterpretation of data. Most of these pitfalls are easily recognized, a few are more tricky. There are some pitfalls specifically related to the equipment, to the guiding catheter used, to the use of the different hyperemic stimuli, and to specific physiolognocturnal 发表于 2025-3-25 01:17:38
https://doi.org/10.1007/978-1-4899-6279-9 ratio to normal maximum flow. In other words: maximum flow in a stenotic coronary artery and maximum flow to the myocardium supplied by that artery are expressed as a fraction of normal maximum coronary and myocardial blood flow (FFR. and FFR., respectively). The main aim of this animal study in do