轨道 发表于 2025-3-25 04:15:39

Accurate Measurement of Cartilage Morphology Using a 3D Laser Scannerg the articular cartilage from which volume, area, and thickness can be computed. We validated the laser scanning approach using a knee model which was covered with a synthetic articular cartilage model and compared the computed volume against water displacement measurements. Using this method, the

POINT 发表于 2025-3-25 08:45:03

http://reply.papertrans.cn/24/2341/234019/234019_22.png

JECT 发表于 2025-3-25 14:44:58

An Integrated Algorithm for MRI Brain Images Segmentationn, and then partition them by a supervised k-Nearest Neighbor (kNN) classifier. This integrated approach yields a robust and precise segmentation. The efficacy of the proposed algorithm is validated using extensive experiments.

Orchiectomy 发表于 2025-3-25 18:50:55

http://reply.papertrans.cn/24/2341/234019/234019_24.png

连词 发表于 2025-3-25 20:21:58

http://reply.papertrans.cn/24/2341/234019/234019_25.png

潜伏期 发表于 2025-3-26 02:48:49

Automatic Reconstruction of Dendrite Morphology from Optical Section Stacksthe reconstructed neuron, a computational model is also created for purposes of performing functional simulations. We present visual and statistical results from reconstructions performed both on real image volumes and on noised synthetic data from the Duke-Southampton archive.

Indigence 发表于 2025-3-26 05:22:20

A Study on the Influence of Image Dynamics and Noise on the JPEG 2000 Compression Performance for Metest images are generated using Poisson statistics; the denoising utilizes a Monte Carlo noise modeling method. A hundred selected images are denoised and the compression ratio, using lossless and lossy JPEG 2000, is reported and evaluated.

Ossification 发表于 2025-3-26 11:57:07

http://reply.papertrans.cn/24/2341/234019/234019_28.png

使增至最大 发表于 2025-3-26 16:42:51

https://doi.org/10.1007/978-1-349-17187-3g the articular cartilage from which volume, area, and thickness can be computed. We validated the laser scanning approach using a knee model which was covered with a synthetic articular cartilage model and compared the computed volume against water displacement measurements. Using this method, the

PAGAN 发表于 2025-3-26 20:19:11

https://doi.org/10.1057/9781137527318tep. The introduced technique was validated with the two dynamic synthetic phantoms simulated based on .C- and .F-labelled tracer distributions. From the quantitative point of view, TAC estimation from the segmented sinograms yielded more accurate results compared to the image-based segmentation.
页: 1 2 [3] 4 5 6 7
查看完整版本: Titlebook: Computer Vision Approaches to Medical Image Analysis; Second International Reinhard R. Beichel,Milan Sonka Conference proceedings 2006 Spri