不溶解 发表于 2025-3-28 17:47:31
Temperature Sensors Based on Plasmonic Photonic Crystal Fibero 53 °C. In addition, the suggested LC-based sensor of compact device length of 20 μm proved to surpass the sensitivity of the recent temperature sensors. Using the LC instead of alcohol has improved the sensitivity to 10 nm/°C. The results are calculated using full-vectorial finite-element method wVulnerable 发表于 2025-3-28 21:33:22
Multifunctional Plasmonic Photonic Crystal Fiber Biosensorse reported multifunctional NLC-based sensor offers high sensitivity of 5 nm/°C and 3700 nm/RIU (refractive index unit) for temperature and analyte refractive index sensing, respectively. In addition, the alcohol mixture PCF sensor achieves high-temperature sensitivity of 13.1 nm/°C with high analyte同位素 发表于 2025-3-29 00:10:40
Development of Photonic Crystal Fiber-Based Gas/Chemical Sensorsal fiber-based gas/chemical sensors, (4) study the effects of different core–cladding shapes, and fiber background materials on sensing performance, and (5) highlight the main challenges of PCF-based gas/chemical sensors and possible solutions.火车车轮 发表于 2025-3-29 06:33:45
http://reply.papertrans.cn/24/2329/232892/232892_44.pngcalumniate 发表于 2025-3-29 08:53:32
http://reply.papertrans.cn/24/2329/232892/232892_45.png者变 发表于 2025-3-29 12:19:28
Viscosity of tetrachloromethane,o 53 °C. In addition, the suggested LC-based sensor of compact device length of 20 μm proved to surpass the sensitivity of the recent temperature sensors. Using the LC instead of alcohol has improved the sensitivity to 10 nm/°C. The results are calculated using full-vectorial finite-element method w荒唐 发表于 2025-3-29 16:47:41
https://doi.org/10.1007/978-3-540-75506-7e reported multifunctional NLC-based sensor offers high sensitivity of 5 nm/°C and 3700 nm/RIU (refractive index unit) for temperature and analyte refractive index sensing, respectively. In addition, the alcohol mixture PCF sensor achieves high-temperature sensitivity of 13.1 nm/°C with high analyteMadrigal 发表于 2025-3-29 22:12:16
https://doi.org/10.1007/978-3-540-75506-7al fiber-based gas/chemical sensors, (4) study the effects of different core–cladding shapes, and fiber background materials on sensing performance, and (5) highlight the main challenges of PCF-based gas/chemical sensors and possible solutions.真实的人 发表于 2025-3-30 00:14:13
http://reply.papertrans.cn/24/2329/232892/232892_49.pnginsolence 发表于 2025-3-30 05:31:55
tudents in the early and intermediate stages working in the areas of photonics, sensors, biophysics, and biomedical engineering; and to biomedical, environmental, and chemical engineers.978-3-030-09522-2978-3-319-76556-3