overture 发表于 2025-3-25 04:49:54

Accounting Control (in R&D Organizations), at the prime number coordinate from a central signal coordinate. Visual evaluation refers to the visibility of the nine signal coordinates when the image is adjusted to fit the monitor’s display. Although digital phantoms have been implemented at 120 facilities, at two other facilities, viewer problems were detected.

阴郁 发表于 2025-3-25 09:54:25

Anticipation of Decision Enforcement,ancer-cases for DM compared with 24 % for DM+DBT for all readers grouped together with reductions also seen for each of the sub-groups. 31 % of normal cases were scored as equivocal in DM compared with 19 % in DM+DBT. Addition of DBT to DM reduces the number of equivocal breast findings regardless of the level of previous DBT experience.

Accrue 发表于 2025-3-25 13:48:11

http://reply.papertrans.cn/20/1907/190603/190603_23.png

Venules 发表于 2025-3-25 18:54:49

http://reply.papertrans.cn/20/1907/190603/190603_24.png

文艺 发表于 2025-3-25 23:27:39

http://reply.papertrans.cn/20/1907/190603/190603_25.png

Morbid 发表于 2025-3-26 02:03:38

http://reply.papertrans.cn/20/1907/190603/190603_26.png

Finasteride 发表于 2025-3-26 07:55:20

Equivocal Breast Findings Are Reduced with Digital Tomosynthesisancer-cases for DM compared with 24 % for DM+DBT for all readers grouped together with reductions also seen for each of the sub-groups. 31 % of normal cases were scored as equivocal in DM compared with 19 % in DM+DBT. Addition of DBT to DM reduces the number of equivocal breast findings regardless of the level of previous DBT experience.

艺术 发表于 2025-3-26 11:50:24

The Accuracy of an Estimating Method for the Mammary Gland Composition in the Mammography Using the ttenuation coefficients from the numbers of input and output photons. These linear attenuation coefficients are plotted in a three-dimensional (3D) scatter plot. Using this 3D scatter plot, we estimate the mammary gland composition and determine the optimal conditions to estimate.

受伤 发表于 2025-3-26 16:36:35

http://reply.papertrans.cn/20/1907/190603/190603_29.png

bisphosphonate 发表于 2025-3-26 16:57:21

Accounting Control (in R&D Organizations),ancers with DBT compared to DM alone screening. Early data on the implementation of synthetic 2D (s2D) imaging coupled with DBT shows maintenance of screening outcomes with reduction in radiation dose compared to DM/DBT screening.
页: 1 2 [3] 4 5 6
查看完整版本: Titlebook: Breast Imaging; 13th International W Anders Tingberg,Kristina Lång,Pontus Timberg Conference proceedings 2016 Springer International Publis