Asseverate 发表于 2025-3-28 17:31:34
1867-8211 019, held in Florence, Italy, in October 2019.. The 27 papers presented were selected from 54 submissions and issue new technologies to provide trustable measuring and communications mechanisms from the data source to medical health databases. Wireless body area networks (WBAN) are one major element惊奇 发表于 2025-3-28 20:48:55
Timothy J. Garrett,William W. Dawsonfrom quantized ECG sequences were constructed in an offline fashion and their performance was evaluated on a set of test signals. The low complexity requirements of the models is confirmed with a port of a pre-trained model of the algorithm into a mobile device without incurring on excessive use of computational resources.绑架 发表于 2025-3-29 00:09:51
Laura K. Hamilton,Karl J. L. Fernandesnd the communication channel itself being the human body in this case. The study is performed over the frequency range 100 kHz–100 MHz, providing the system designer with a unique guide for the relationship between the system parameters, thus facilitating the design of an efficient and better matched system components.perjury 发表于 2025-3-29 06:58:03
Arrhythmia Detection with Antidictionary Coding and Its Application on Mobile Platformsfrom quantized ECG sequences were constructed in an offline fashion and their performance was evaluated on a set of test signals. The low complexity requirements of the models is confirmed with a port of a pre-trained model of the algorithm into a mobile device without incurring on excessive use of computational resources.格言 发表于 2025-3-29 10:28:05
Sensitivity of Galvanic Intra-Body Communication Channel to System Parametersnd the communication channel itself being the human body in this case. The study is performed over the frequency range 100 kHz–100 MHz, providing the system designer with a unique guide for the relationship between the system parameters, thus facilitating the design of an efficient and better matched system components.点燃 发表于 2025-3-29 11:58:53
http://reply.papertrans.cn/19/1896/189535/189535_46.pngLipohypertrophy 发表于 2025-3-29 15:44:28
A Piezoelectric Heart Sound Sensor for Wearable Healthcare Monitoring Devicesain vital physiological and pathological evidence about health. Many existing techniques are not suitable for long-term dynamic heart sound monitoring since their large size, high-cost and uncomfortable to wear. This paper proposes a small, low-cost and wearable piezoelectric heart sound sensor, whi假设 发表于 2025-3-29 22:24:29
Vertical Hand Position Estimation with Wearable Differential Barometery Supported by RFID Synchronizcy in the range of 30 cm. To this end, the two barometers synchronized each time an RFID reader detects them being in proximity of each other. The accuracy is sufficient to detect a specific shelve of a cupboard on which something has been placed or determine if the user’s hand is touching his/her h去才蔑视 发表于 2025-3-30 00:09:34
http://reply.papertrans.cn/19/1896/189535/189535_49.png有恶臭 发表于 2025-3-30 04:25:41
Arrhythmia Detection with Antidictionary Coding and Its Application on Mobile Platformsvices, an implementation of the antidictionary coding algorithm for memory constrained devices is presented. Pre-trained . probabilistic models built from quantized ECG sequences were constructed in an offline fashion and their performance was evaluated on a set of test signals. The low complexity r