amyloid 发表于 2025-3-28 16:12:32
Tipologie di referti: il razionale,ng to micro mixing systems intimately attached to micro resonant structures. The characteristics of resonant structures dedicated to close attachment of liquid mixing systems with low dead volumes, short mixing times, and minimal microwave microphonic perturbation are outlined. The application of su退潮 发表于 2025-3-28 20:10:09
http://reply.papertrans.cn/19/1881/188010/188010_42.pngExposition 发表于 2025-3-28 23:54:32
https://doi.org/10.1007/978-88-470-1108-3g source, can be used in a field swept display to monitor saturation-transfer mechanisms such as Heisenberg Exchange, nitrogen nuclear relaxation, and rotational diffusion. 2D pulse ELDOR techniques known as DEER or PELDOR using two separate microwave frequencies or a similar “2 + 1” technique using休息 发表于 2025-3-29 06:49:35
Tecnica radiologica: quali scenari oggi?,aded instrument performance. The use of digital technology is making superheterodyne detection increasingly attractive, relative to homodyne detection, which has been used in most “modern” EPR spectrometers. The signal modulation frequency, the sampling, frequency, and the intermediate frequency (frInflated 发表于 2025-3-29 09:27:37
,L’informazione clinica per un buon referto,re available to measure distances between two slowly relaxing centers or between a rapidly relaxing center and a slowly relaxing center. An overview of these methods is provided with an emphasis on recent examples that demonstrate the power of these techniques.游行 发表于 2025-3-29 14:54:36
Indici di gradimento del prescrittore,spin label at a specifically-placed amino acid residue in a peptide or protein. In most cases a sulfhydryl-specific spin label is bound to a cysteine side chain. Such specific placement monitors a local environment via the usual parameters of a nitroxyl spin label such as sensitivity to motion, spin子女 发表于 2025-3-29 16:00:08
https://doi.org/10.1007/978-88-470-1108-3 present day. Initial methodological development was by Hyde and Dalton, followed by the introduction into biology by Hyde and Thomas. ST-EPR is a continuous wave spectroscopy, which extends the sensitivity of conventional nitroxide EPR to the microsecond (or submillisecond) correlation time regimeLEVER 发表于 2025-3-29 19:47:40
La comunicazione radiologica odierna,st three decades. Development of computational algorithms for analyzing the ST-EPR data from membrane proteins undergoinguniaxial rotational diffusion and inclusion of these algorithms into global nonlinear least squares fitting routines has permitted detailed analyses of experimental data. These ad锉屑 发表于 2025-3-30 00:56:00
http://reply.papertrans.cn/19/1881/188010/188010_49.pngaudiologist 发表于 2025-3-30 07:20:15
https://doi.org/10.1007/b111471ENDOR; ESR; electron spin; molecule; spectroscopy