懒惰民族 发表于 2025-3-26 21:21:46

HYDROWEB, an Online Tool for the Calculation of Hydrodynamic Properties of Macromolecules use for less computer experienced users. With this objective in mind we have developed HYDROWEB, a tool that easily allows to work with hydrodynamic models of macromolecules and the calculation of their properties (using the softwares HYDROPRO, HYDRO++ and SIMUFLEX) and convenient visualization of its results. The tool can be accessed at ..

lipoatrophy 发表于 2025-3-27 02:37:13

,Hauptsache Hauptsätze - Der 1. Hauptsatz,onstrate the device’s potential for metabolic rate breath analysis. The O. sensor is not able to follow changes in O. concentration during the breathing cycle; however, the newly developed affordable and low-power consumption CO. sensor performs comparably to a bulky, high power consumption commercial device.

王得到 发表于 2025-3-27 06:33:57

https://doi.org/10.1007/978-3-8348-9420-5ss the impact of the partial coverage of the vaccination program. This is of paramount importance because, from the Public Health point of view, the herd immunity may be an undesirable effect of the partial vaccination due to that varicella and/or herpes zoster in adults use to be severe.

易改变 发表于 2025-3-27 10:21:01

http://reply.papertrans.cn/19/1872/187181/187181_34.png

enlist 发表于 2025-3-27 14:07:37

Studying the Herd Immunity Effect of the Varicella Vaccine in the Community of Valencia, Spainss the impact of the partial coverage of the vaccination program. This is of paramount importance because, from the Public Health point of view, the herd immunity may be an undesirable effect of the partial vaccination due to that varicella and/or herpes zoster in adults use to be severe.

Desert 发表于 2025-3-27 20:35:07

http://reply.papertrans.cn/19/1872/187181/187181_36.png

bacteria 发表于 2025-3-28 00:20:34

http://reply.papertrans.cn/19/1872/187181/187181_37.png

CEDE 发表于 2025-3-28 04:37:33

Development of a Handheld Side-Stream Breath Analyser for Point of Care Metabolic Rate Measurementonstrate the device’s potential for metabolic rate breath analysis. The O. sensor is not able to follow changes in O. concentration during the breathing cycle; however, the newly developed affordable and low-power consumption CO. sensor performs comparably to a bulky, high power consumption commercial device.

DOSE 发表于 2025-3-28 10:20:00

The Complexity of Some Pattern Problems in the Logical Analysis of Large Genomic Data Setsiated to the rows. An important case is when the rows are also labeled into two groups, namely the . (or healthy) and the . (or diseased) samples. The . (LAD) is a procedure aimed at identifying relevant features and building boolean formulas (rules) which can be used to classify new samples as posi

不能平静 发表于 2025-3-28 11:21:56

Development of a Handheld Side-Stream Breath Analyser for Point of Care Metabolic Rate Measurementative humidity and gas flow rate. Metabolic rate can be calculated from the inspired and expired gas concentrations; a knowledge of this over a 24 h period can guide calorific intake. The analyser provides easy-to-read results on either a laptop or smart phone. Results for the O. and CO. sensors dem
页: 1 2 3 [4] 5 6 7
查看完整版本: Titlebook: Bioinformatics and Biomedical Engineering; 4th International Co Francisco Ortuño,Ignacio Rojas Conference proceedings 2016 Springer Interna