借喻 发表于 2025-3-28 18:03:55

Intravascular Ultrasound Applications for Endoaortic Surgery,nd transducer emits and receives signals at 12.5, 20, or 30 MHz, producing an axial image (or frame) similar to cuts from computed tomography (CT) and magnetic resonance imaging (MRI). Increased MHz size results in a more detailed image (“Near vision”), whereas a lower MHz results in more penetration with a larger field of view.

vibrant 发表于 2025-3-28 19:45:43

Book 2013linical case scenarios as well as controversies to highlight the use of this new technology. The various aortic pathologies are discussed, combining etiology, diagnostic tools like intravascular ultrasound (IVUS) and 64 slice CT scans which are all state of the art technologies, endovascular treatme

jaundiced 发表于 2025-3-29 00:42:08

Spinal Cord Protection, 5.4 % vs. 14 % with a 30 % reduction risk of paraplegia for endografts cohorts (Walsh et al. 2008). Paraplegia pathophysiology was firstly focused on the integrity of the artery of Adamkiewicz (see Fig. 6.1).

prolate 发表于 2025-3-29 05:07:21

Book 2013tiology, diagnostic tools like intravascular ultrasound (IVUS) and 64 slice CT scans which are all state of the art technologies, endovascular treatment, management of endoleaks, reinterventions combined with techniques of trouble shooting. This book highlights the new changes in the management of thoracic aortic diseases.

善于骗人 发表于 2025-3-29 09:07:56

http://reply.papertrans.cn/17/1641/164057/164057_45.png

单纯 发表于 2025-3-29 14:45:27

se scenarios as well as controversies to highlight the use oThere is no standard textbook at this time on endovascular management of thoracic aortic pathologies. Atlas of Thoracic Aortic Endografting contains clinical case scenarios as well as controversies to highlight the use of this new technolog

BANAL 发表于 2025-3-29 18:32:00

http://reply.papertrans.cn/17/1641/164057/164057_47.png

悦耳 发表于 2025-3-29 21:58:41

Takuya Miura,Rintaro Ueji,Hidetoshi Fujiiiac. The latter case is a more complex one: due to the extreme tortuosity of the iliac axes, a retroperitoneal approach was performed to straighten the access arteries, allowing a smoother advancement of the endograft.

CESS 发表于 2025-3-30 02:23:56

I. Kalemba,C. Hamilton,S. Dymekis a rupture of the thoracic aorta. Two acute aortic type B dissection cases were managed with a covered stent-graft to exclude the primary entry tear associated with uncovered stents to cover the remaining aorta. Due to the absence of adequate proximal neck in the first dissection case, a carotid to subclavian bypass was necessary.

Nucleate 发表于 2025-3-30 06:03:02

http://reply.papertrans.cn/17/1641/164057/164057_50.png
页: 1 2 3 4 [5] 6
查看完整版本: Titlebook: Atlas of Advanced Endoaortic Surgery; Jacques Kpodonu,Stéphan Haulon Book 2013 Springer-Verlag London 2013