散步 发表于 2025-3-28 14:42:20
http://reply.papertrans.cn/17/1635/163471/163471_41.pngureter 发表于 2025-3-28 21:17:50
Lecture Notes in Computer Sciences in balloon catheter design intended to minimize associated vascular complications, advances in balloon pump drivers designed to enhance effectiveness and facilitate machine operation, and progress toward a permanent version of the balloon pump (the mechanical auxiliary ventricle) for progressive, refractory chronic heart failure.STALL 发表于 2025-3-29 01:19:41
http://reply.papertrans.cn/17/1635/163471/163471_43.png分贝 发表于 2025-3-29 04:43:15
Program Generation and Components,ransplantation that there has been decreasing use as the requirements for longer support (30 days +) and patient mobility have become apparent. Even in some of these patients, however, centrifugal pumps are still briefly deployed to stabilize the patient prior to the decision to utilize a more durable implantable system.Exhilarate 发表于 2025-3-29 09:15:40
Book 1995f an ongoing effort by the editors to keep readers regularly informed of recent developments in the field. Assisted Circulation is a standard technology in cardiac surgery and especially in cardiac transplantation.bromide 发表于 2025-3-29 12:18:11
http://reply.papertrans.cn/17/1635/163471/163471_46.png细节 发表于 2025-3-29 17:14:59
http://reply.papertrans.cn/17/1635/163471/163471_47.png冰河期 发表于 2025-3-29 21:10:17
Formal Methods for Components and Objects]. If, therefore, pressure during ventricular ejection could be reduced, oxygen consumption could also be reduced, provided mean arterial perfusion pressure was maintained at the same level. This principle has been used in the only method of assistance to gain acceptance as a standard clinical therapy, intra-aortic balloon pumping .不能逃避 发表于 2025-3-30 03:24:15
https://doi.org/10.1007/978-3-642-17071-3 one hand and intraventricular balloon shape and volume on the other appears to exist . The selection of an optimal balloon shape and volume is not always easy, despite the use of echocardiography prior to its insertion . Thus, additional pumping into the aorta may be needed .enfeeble 发表于 2025-3-30 05:21:31
Property-Based Testing - The ProTest Projectrtner) or a moving diaphragm (Pierce, Unger, Frazier, Whalen) (Table 1). The driving source is either pneumatic or electromechanical via a tube through the skin. In the electromechanical driving mode, the incorporated devices need a compliance chamber. Furthermore, nonpulsatile blood pumps are also available.