Confound 发表于 2025-3-25 07:14:24

Expert Oracle Database Architecturent population. Typically, these patients are encountered after several previous surgeries with complaints including persistent pain, instability, and general wrist dysfunction. In this chapter, we propose six interrelated zones to frame evaluation of the failed DRUJ arthroplasty (nerve, tendon, adja

蕨类 发表于 2025-3-25 08:12:04

http://reply.papertrans.cn/17/1620/161929/161929_22.png

agenda 发表于 2025-3-25 13:03:58

https://doi.org/10.1007/978-1-4302-2947-6s, surgery may be indicated. Although many different procedures have been described over the years, resection of the trapezium is often part of them, and this procedure remains the gold standard. The reported outcome is good, but recovery time is often prolonged, and a significant number of patients

说不出 发表于 2025-3-25 16:59:28

Expert Oracle Database Architecturer irreparable distal humeral fractures including mal- or nonunions. Design considerations related to fixation and stem shape for hemiarthroplasty are comparable to TEA. While implant wear itself does not occur, cartilage wear of the ulna and radius is a concern. If needed conversion to TEA is possible.

稀释前 发表于 2025-3-25 21:10:33

Expert Oracle Database Architecturead categories of surgical treatment: partial or complete resection of the distal ulna (hemiresection with soft tissue interposition or the Darrach procedure), arthrodesis of the DRUJ with ulnar neck resection (Sauve-Kapandji procedure), and partial or complete arthroplasty (ulnar head replacement or total DRUJ replacement).

小淡水鱼 发表于 2025-3-26 01:50:14

https://doi.org/10.1007/978-1-4302-2947-6uccessful clinical results have been published, which has provoked a growing interest in these procedures. Possible complications such as dislocation, polyethylene wear, and cup loosening are rare with good implant selection and correct surgical technique, but follow-up studies beyond 15 years are needed.

慢跑 发表于 2025-3-26 08:17:24

Total Elbow Arthroplasty: Design Considerationsr irreparable distal humeral fractures including mal- or nonunions. Design considerations related to fixation and stem shape for hemiarthroplasty are comparable to TEA. While implant wear itself does not occur, cartilage wear of the ulna and radius is a concern. If needed conversion to TEA is possible.

男学院 发表于 2025-3-26 09:00:12

http://reply.papertrans.cn/17/1620/161929/161929_28.png

Hypopnea 发表于 2025-3-26 12:40:30

http://reply.papertrans.cn/17/1620/161929/161929_29.png

欺骗世家 发表于 2025-3-26 16:59:14

Primary Total Wrist Arthroplastyand design and on the correct handling and reconstruction of the periarticular capsular, ligamentous, and tendon structures. Postoperative rehabilitation is carried out with the assistance of a hand therapist and appropriate splinting techniques.
页: 1 2 [3] 4 5 6
查看完整版本: Titlebook: Arthroplasty of the Upper Extremity; A Clinical Guide fro Graham J. W. King,Marco Rizzo Book 2021 Springer Nature Switzerland AG 2021 Basal