伴随而来 发表于 2025-3-28 17:24:53

http://reply.papertrans.cn/17/1620/161926/161926_41.png

novelty 发表于 2025-3-28 20:03:24

http://reply.papertrans.cn/17/1620/161926/161926_42.png

myalgia 发表于 2025-3-29 02:57:30

http://reply.papertrans.cn/17/1620/161926/161926_43.png

厌烦 发表于 2025-3-29 03:31:52

Conference proceedings 2001 .Arthroplasty . .2000. also takes up current controversial issues such as posterior cruciate substitution versus retention in TKA. With contributions by eminent specialists in total joint replacement in Asia, Europe, and North America, this volume is a valuable reference for all orthopedic surgeons.

公社 发表于 2025-3-29 11:11:04

http://reply.papertrans.cn/17/1620/161926/161926_45.png

certain 发表于 2025-3-29 12:22:48

The Logic of Conditional Obligationintroduction of the Robodoc Pinless System at BGU Frankfurt in mid-1998. The system also contains a revision software. Now, the pinless procedure has become everyday routine at BGU just like the pin-based procedure.

开始没有 发表于 2025-3-29 16:27:59

Wear of Alumina-on-Alumina Total Hip Prosthesis: Effect of Diametrical Clearance and Lubricant on Hi bovine serum were 0.0015 and 0.004 mm. Vmillion cycles, respectively; and “run-in” and “steady-state” wear rates in 90% bovine serum were threefold higher than those in saline. Alumina-on-alumina wear was extremely low in diametrical clearance between 10 to 100μm in both saline and bovine serum.

anaerobic 发表于 2025-3-29 23:15:13

Computer-Assisted Procedures in Orthopedic Surgeryintroduction of the Robodoc Pinless System at BGU Frankfurt in mid-1998. The system also contains a revision software. Now, the pinless procedure has become everyday routine at BGU just like the pin-based procedure.

宽敞 发表于 2025-3-30 01:49:00

Cross-Linked UHMWPE on Alumina Total Hip Arthroplasty with 50–150 Mrad did not show detectable wear. Wear of ultrahigh molecular weight polyethylene (UHMWPE) irradiated with 6.5 Mrad (Aeonian) decreased to 3% by the hip simulator test without deterioration of physical properties. Oxidation caused by free radicals produced by gamma-ray sterilization was extremely low.

才能 发表于 2025-3-30 05:42:51

Preoperative Simulation System for the ZCHW Custom Hip Prosthesis and Its Usage Through the Internetpreoperative simulation system was developed to determine if there were problems, and the system was refined so as to be able to use it over the Internet. In this article, the results of these cases and the utility of the preoperative simulation system are presented.
页: 1 2 3 4 [5] 6
查看完整版本: Titlebook: Arthroplasty 2000; Recent Advances in T Nobuo Matsui (Professor and Chairman),Yoichi Taned Conference proceedings 2001 Springer-Verlag Toky