Frequency-Range 发表于 2025-3-25 11:18:13

Pooja Sharma,Surendra Pratap Singh turbine generator (or wind-driven compressor) to supply heat for moderate temperature thermal processes..The use of a working fluid of variable composition in a compression heat pump makes possible the abstraction of heat at useful temperatures over a range of compressor work inputs. Such a system

floaters 发表于 2025-3-25 13:36:56

http://reply.papertrans.cn/16/1593/159214/159214_23.png

争吵加 发表于 2025-3-25 17:01:52

Srinivas Tanuku,K. Rama Mohana Raoerformance (cop) varies from 1.05 to 1.56. The primary energy saved by the HPS with respect to a conventional heating system was 11%, 16% and 16% in these three heating seasons, versus values of 16%, 24% and 27%, respectively, expected for a cop of 1.45 and regular HPS operation. The scientific rese

Affiliation 发表于 2025-3-25 23:10:32

http://reply.papertrans.cn/16/1593/159214/159214_25.png

Parameter 发表于 2025-3-26 01:41:37

http://reply.papertrans.cn/16/1593/159214/159214_26.png

Resection 发表于 2025-3-26 05:44:41

A ‘Self-Regulating’ Heat Pump for Renewable Energy Applications turbine generator (or wind-driven compressor) to supply heat for moderate temperature thermal processes..The use of a working fluid of variable composition in a compression heat pump makes possible the abstraction of heat at useful temperatures over a range of compressor work inputs. Such a system

BOON 发表于 2025-3-26 09:50:07

Ethylchloride: A Viable Alternative for Medium and High-Temperature Compression Heat Pump Cyclesion and greenhouse effect are expected..First results in an experimental test rig, corroborating the theoretical findings, will be presented as well as results of material compatibility tests. In these tests, ethylchloride shows high potential for posing a viable alternative for medium and high temp

averse 发表于 2025-3-26 13:07:39

Heat Pumps with Different Energy Collectors in Army Barracks (Volkach, Germany): Results from Three erformance (cop) varies from 1.05 to 1.56. The primary energy saved by the HPS with respect to a conventional heating system was 11%, 16% and 16% in these three heating seasons, versus values of 16%, 24% and 27%, respectively, expected for a cop of 1.45 and regular HPS operation. The scientific rese

transient-pain 发表于 2025-3-26 20:34:59

Predictive Control of a Hybrid Heating System Including a Heat Pumplify both the solution of the optimization problem, and the mathematical model..Different control structures are compared regarding exergy consumption, and it is shown how these control structures influence the various exergy losses in the heating system..A sensitivity analysis is performed, where d