venous-leak 发表于 2025-3-25 06:43:40

Board of International Research in DesignInstallation of a shunt thyristor-controlled reactive power compensator, the static VAR compensator (SVC), is for the voltage support at a key location in a power system. An additional stabilizing signal can be superimposed on the voltage control loop of the SVC to provide extra damping to the power system.

DAUNT 发表于 2025-3-25 08:12:30

Board of International Research in DesignFigure . shows the configuration of a shunt voltage source converter (VSC)-based unit connected to high-voltage transmission line through a step-down transformer. x. is the equivalent reactance of the step-down transformer.

Explosive 发表于 2025-3-25 11:57:52

Board of International Research in DesignFigure . shows an N-machine power system with nodes of internal voltage of generators added. From Fig. ., the following network equations can be established.

高脚酒杯 发表于 2025-3-25 16:27:12

http://reply.papertrans.cn/16/1562/156172/156172_24.png

转换 发表于 2025-3-25 21:42:11

Damping Torque Analysis of Thyristor-Based FACTS Stabilizers Installed in Single-Machine Infinite-BInstallation of a shunt thyristor-controlled reactive power compensator, the static VAR compensator (SVC), is for the voltage support at a key location in a power system. An additional stabilizing signal can be superimposed on the voltage control loop of the SVC to provide extra damping to the power system.

Aura231 发表于 2025-3-26 01:04:05

http://reply.papertrans.cn/16/1562/156172/156172_26.png

内阁 发表于 2025-3-26 04:29:12

http://reply.papertrans.cn/16/1562/156172/156172_27.png

Substance 发表于 2025-3-26 10:31:48

Introduction,the oscillation frequency from 0.1 Hz up to a couple of Hz. Once started, the oscillations can continue for a while and then disappear, or grow continuously to cause power system collapse. In this book, they are called power system oscillations or power oscillations for short.

较早 发表于 2025-3-26 14:42:23

A Multi-machine Power System Installed with Power System Stabilizers,stem is used in this section to demonstrate the procedure of establishing the mathematical model of a multi-machine power system. Later, it will be used for introducing basic concepts and methods in the analysis of power system oscillations and design of PSSs in the multi-machine power system. For t

甜得发腻 发表于 2025-3-26 19:34:45

Multi-machine Power Systems Installed with VSC-Based Stabilizers,n Fig. .. The shunt VSC can be connected to an energy storage system (ESS), a HVDC, or a static renewable power station, such as a photovoltaic (PV) or fuel cell (FC) power station. It can operate alone as a VSC-based FACTS device, STATCOM (see Sect. .).
页: 1 2 [3] 4
查看完整版本: Titlebook: Analysis and Damping Control of Power System Low-frequency Oscillations; Haifeng Wang,Wenjuan Du Book 2016 Springer Science+Business Media