Blatant 发表于 2025-3-25 04:44:26

Determination of Sulfur Amino Acids, Glutathione, and Related Aminothiols in Biological Samples by to the analysis of biological samples. As the HPLC methods, the ultraviolet (UV) (.–.), and the postcolumn UV derivatization with 4,4′-dithiopyridine (.) and 5,5-dithiobis (2-nitrobenzoic acid) (.), the precolumn fluorescence derivatization with 4-(aminosulfonyl)- or ammonium-7-fluoro-2,1,3-benzoxad

glucagon 发表于 2025-3-25 10:19:50

Capillary Electrophoretic Determination of 4-Hydroxyproline,ard the cathode with substantial velocity. This results in the flow of water termed electroosmosis. The flow proceeds from the anode to the cathode and serves as a pump. Because the electroosmotic water flow is much greater than the velocity of the analytes, all components are swept to the cathode.

Contort 发表于 2025-3-25 14:53:51

https://doi.org/10.1007/978-3-642-48550-3only used to recover proteins from buffers: a gel filtration method, Ultra microspin columns, and adsorption to a polyvinylidene difluoride (PVDF) membrane in the ProSorb sample preparation cartridge from Applied Biosystems. Both methods work well, with somewhat better recoveries for the gel filtrat

骚动 发表于 2025-3-25 17:09:50

https://doi.org/10.1007/978-3-663-05097-1n the method described here amino acids in standards, urine, or deproteinized serum/plasma are reacted with phenylisothiocyanate (PITC) in the presence of a coupling solvent. The phenylthiocyanate (PTC) derivatives are then applied to a reverse-phase (RP) HPLC column and separated using a gradient e

平淡而无味 发表于 2025-3-25 21:32:55

Die Industrie der Steinkohlenveredelung amino acid derivatives are stable for months when stored dry at −20°C, or for days in solution at ambient temperature (.,.). This approach can be used conveniently for analysis of lipid-rich material, where at least 300 samples can be analyzed with the same column, i.e., the column lifetime is comp

foodstuff 发表于 2025-3-26 00:17:58

http://reply.papertrans.cn/16/1547/154680/154680_26.png

千篇一律 发表于 2025-3-26 07:43:42

http://reply.papertrans.cn/16/1547/154680/154680_27.png

Compatriot 发表于 2025-3-26 10:58:44

https://doi.org/10.1007/978-3-662-33208-5ard the cathode with substantial velocity. This results in the flow of water termed electroosmosis. The flow proceeds from the anode to the cathode and serves as a pump. Because the electroosmotic water flow is much greater than the velocity of the analytes, all components are swept to the cathode.

Valves 发表于 2025-3-26 15:45:24

http://reply.papertrans.cn/16/1547/154680/154680_29.png

Coeval 发表于 2025-3-26 19:44:39

Book 2000imental results, and contains helpful notes on pitfalls to avoid, and variations that enable the methods to be used with different systems..Up-to-date and highly practical, Amino Acid Analysis Protocols offers analytical and clinical chemists, as well as a broad range of biological and biomedical in
页: 1 2 [3] 4 5 6 7
查看完整版本: Titlebook: Amino Acid Analysis Protocols; Catherine Cooper,Nicolle Packer,Keith Williams Book 2000 Humana Press 2000