saphenous-vein 发表于 2025-3-25 06:38:12

https://doi.org/10.1007/978-3-658-32225-0y the local concentration of the contrast agent administered and the measurement sequence used but also by MR-specific processes, such as proton relaxation enhancement and water exchange between tissue compartments. It was thus the aim of our investigation to assess the reliability of an MRI approac

Bridle 发表于 2025-3-25 10:52:52

http://reply.papertrans.cn/15/1489/148881/148881_22.png

Cytology 发表于 2025-3-25 15:05:30

The hydromagnetic approximation,n neurosurgery. It usually affects the planning and performing of surgery as both is conventionally based on preoperative patient data sets. Thus, an online acquisition and processing of data during surgery is needed to increase navigational accuracy. Beside cost-intensive solutions like intraoperat

perimenopause 发表于 2025-3-25 18:57:58

Alternating current in a magnetoplasma, experiments are essential. The isometric force measurement commonly used to analyse the vasoconstriction of isolated blood vessels can not be applied in the . situation. In contrast Optical Coherence Tomography (OCT) allows the acquisition of 2D cross sectional images und 3D cross sectional image s

凝视 发表于 2025-3-25 20:52:40

http://reply.papertrans.cn/15/1489/148881/148881_25.png

桶去微染 发表于 2025-3-26 02:30:40

https://doi.org/10.1007/978-3-540-75136-6y. Secondary radiation forces, resulting from oscillating microbubbles under ultrasound insonification, may cause the mutual attraction and subsequent coalescence of contrast microbubbles. This phenomenon has been less studied. Microbubbles with a negligible shell can be forced to translate towards

大炮 发表于 2025-3-26 05:52:21

Jianli Song,Zhiqi Liu,Yongtang Liwards to process and to visualise these data on an autostereoscopic 3D-display with the possibility to navigate interactively with a 3D-mouse in the virtual data space. The system shall be used in operation planning and intraoperative navigation in neurosurgery. To determine the precision of the ima

疲劳 发表于 2025-3-26 08:27:31

Cold Sprayed Metal Matrix Composites,l of the CCD chip interacts with the X-ray photons via photoelectric absorption and Compton scattering, it is not clear if these interactions produce irreversible damages within a typical working window in all day use in a clinical environment. The present study was accomplished at the X-ray Lab of

INCUR 发表于 2025-3-26 13:32:42

Commercial Cold Spray Equipment,approach could be mandatory for future combined PET and MRI scanners, which probably do not include a transmission facility. T1-weighted MR images were segmented into brain tissue, bone, soft tissue, and sinus; attenuation coefficients corresponding to elemental composition and density as well as to

地壳 发表于 2025-3-26 17:03:42

Materials Forming, Machining and Tribologyunctional areas. Preoperative intervention planning in brain tumours poses many additional challenges if the goal is to include functional data from PET for neuronavigation: co-registration of multimodal image data (MRI and PET) is conceptually the most demanding task. However, we find that associat
页: 1 2 [3] 4 5 6 7
查看完整版本: Titlebook: Advances in Medical Engineering; Thorsten M. Buzug,Dietrich Holz,Simone Weber Conference proceedings 20071st edition Springer-Verlag Berli