Bilateral-array focused ultrasound transducer with dual-frequency mode for blood-brain barrier openl-frequency mode in presence of micro-bubbles (MB). Both diameter and radius of curvature for the ultrasound transducer are 10.0cm, and the driving frequency is 10kHz difference for the left and the right elements to generate an oscillatory-amplitude focal zone. The ultrasound sonication parameters种属关系 发表于 2025-3-30 17:48:49
CALIBRATION OF THE MAGNETIC TRACKER FOR ACQUISITION OF 3D IMAGES TO GUIDE NEUROSURGERIES,ily to obtain important points for the execution of Computer Assisted Neuro-Surgery using 3D Images (CANS); as well as the reconstruction of three-dimensional objects inside a Virtual Reality environment. Following the calibration, the movements acquired by the sensor are tracked by the computer inmenopause 发表于 2025-3-30 22:18:43
Temperature mapping for MR-guided radiofrequency ablation - how accurate can cell necrosis be monitnecrosis..Ten patients with primary and secondary liver lesions were treated by MR-guided radiofrequency (RF) ablation. A gradient echo sequence was used to calculate temperature maps (n=22) in the plane of the RF applicators (n=10) and in a plane perpendicular to them (n=12), based on the proton re委派 发表于 2025-3-31 03:52:31
http://reply.papertrans.cn/104/10312/1031116/1031116_55.png勾引 发表于 2025-3-31 08:57:51
Feasibility and Medical Impact Assessment of Handheld-Mobile-Robot usage in Image Guided Craniotomy precision craniotomy path profiles directly to the patient, with minimum modifications to the surgeons workflow, and without the large impact on the Operating Room (OR) of current Surgical Robots. Performed here is an assessment on how feasible this mobile robot is in attaining adequate traction on过于平凡 发表于 2025-3-31 12:33:23
http://reply.papertrans.cn/104/10312/1031116/1031116_57.pnggimmick 发表于 2025-3-31 13:38:09
Using microbubble contrast agent of different dosage to enhancing liver ablation induced by high-inU) ablation in goat livers in vivo. Methods: Twenty goats were divided into 4 groups randomly. Animals in group 1, 2 and 3 were bolus-injected with 0.01ml/kg/dot, 0.03ml/kg/dot and 0.05ml/kg/dot of SonoVue (Bracco SpA, Milan, Italy) intravenously respectively before HIFU exposure; and those in group比赛用背带 发表于 2025-3-31 17:56:15
http://reply.papertrans.cn/104/10312/1031116/1031116_59.pnginundate 发表于 2025-3-31 22:22:30
Robotic Magnetic Manoeuvring of Endoscopic Video Capsules: Phantom Tests, on ingestible capsules that allow comfortable gastrointestinal explorations. Despite their attractive capabilities, capsule endoscopes still show today a serious technical lack, which limits their clinical efficacy: their motion can not be controlled. Their movements and orientations are completely