剥削
发表于 2025-3-26 23:21:31
2366-2557 gth of FRB bars, structural shapes and fully composite bars, etc. This volume will prove a valuable resource for those in academia and industry..978-3-031-09411-8978-3-031-09409-5Series ISSN 2366-2557 Series E-ISSN 2366-2565
Arctic
发表于 2025-3-27 02:48:14
http://reply.papertrans.cn/11/1012/101130/101130_32.png
Canary
发表于 2025-3-27 07:50:40
11. Tagung Einspritzung und Kraftstoffe 2018bridge is composed of the assembly of three different floating bridge structures: The Heavy Communication Bridge (HCB), the assault floating bridge (PMM71), and both are connected using a pontoon unit named New Connection Pontoon (NCP). The NCP is fully manufactured of steel sheets and sections and
dictator
发表于 2025-3-27 13:17:37
11. Tagung Einspritzung und Kraftstoffe 2018ating bond condition. Signal analysis of the recorded data showed consistent frequencies and decaying sinusoidal waveforms for bonded CFRP plates. De-bonded CFRP plates had lower frequencies with faster decaying waveforms. Test data shows the impact acoustic emission frequencies and waveform damping
inspiration
发表于 2025-3-27 16:50:49
Michael Willmann,Hartmut Schneidergthen concrete beams, deficient in flexure. These charts are derived to be compatible with the Canadian building codes (NBCC .; CSA S806-17). A database of experimentally tested strengthened beams is collected, applied along with the statistics for unstrengthened beams and loads, used to calibrate t
裂隙
发表于 2025-3-27 20:59:23
http://reply.papertrans.cn/11/1012/101130/101130_36.png
CHASE
发表于 2025-3-28 00:22:18
http://reply.papertrans.cn/11/1012/101130/101130_37.png
伙伴
发表于 2025-3-28 04:10:41
Nachhaltige Transformation im Quartier the gripped CFRP plate. In this paper, a three-dimensional FE model was developed and verified. The symmetric model consisted of a CFRP plate, a copper sleeve, a steel wedge, and a steel barrel. Different experimentally verified contact conditions were applied at the CFRP-sleeve, sleeve-wedge, and
创作
发表于 2025-3-28 09:07:35
https://doi.org/10.1007/978-3-658-23446-1in compliance with CAN/ULC S101 standard. Each beam was subjected to 85% of the beam ultimate design load. The experimental results and time to failure of the two beams when subjected to standard fire exposure were compared to those of identical beams subjected to only 40% of the beam ultimate desig
最低点
发表于 2025-3-28 14:18:28
Nachhaltige Transformation im Quartierperties. Scanning electron microscope was used to observe the microstructure of the repairs. The results indicate that after 26-year long service life, the condition of CFRP repairs considerably deteriorated.